Document Citation: 14 CFR 23.1359

Header:
CODE OF FEDERAL REGULATIONS
TITLE 14 -- AERONAUTICS AND SPACE
CHAPTER I -- FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION
SUBCHAPTER C -- AIRCRAFT
PART 23 -- AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEG

Date:
02/28/2013

Document:
§ 23.1359 Electrical system fire protection.


(a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182.

(b) Electrical cables, terminals, and equipment in designated fire zones that are used during emergency procedures must be fire-resistant.

(c) Insulation on electrical wire and electrical cable must be self-extinguishing when tested at an angle of 60 degrees in accordance with the applicable portions of Appendix F of this part, or other approved equivalent methods. The average burn length must not exceed 3 inches (76 mm) and the average flame time after removal of the flame source must not exceed 30 seconds. Drippings from the test specimen must not continue to flame for more than an average of 3 seconds after falling.